Connecting Xscf Cables - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

4.2.2

Connecting XSCF cables

There are two types of XSCF cables: DUAL cable and XSCF BB control cable. Connect
XSCF cables according to the following procedure. Connect the cables such that the
port indications on each chassis match the labels on the cables.
1.
Connect the XSCF DUAL control cable between the XSCF of BB#00 and the
XSCF of BB#01.
a. Connect the XSCF DUAL cable from the BB#00 DUAL port to the BB#01
2.
For the 2BB configuration, connect an XSCF BB control cable between the
XSCF of BB#00 and the XSCF of BB#01.
a. Connect the cable from port 0 of BB#00 to port 0 of BB#01.
3.
For the 3BB configuration, connect XSCF cables to XSCF ports of BB#02, in
addition to the connection of step 2.
a. Connect the cable from port 1 of BB#00 to port 0 of BB#02.
b. Connect the cable from port 1 of BB#01 to port 1 of BB#02.
4.
For the 4BB configuration, connect XSCF cables to XSCF ports of BB#03, in
addition to the connections of steps 2 and 3.
a. Connect the cable from port 2 of BB#00 to port 0 of BB#03.
b. Connect the cable from port 2 of BB#01 to port 1 of BB#03.
Figure 4-5     XSCF port location diagram (chassis rear)
DUAL port.
The DUAL ports are marked DUAL.
Chapter 4 Configuring Building Block Connections