Mitsubishi Electric GOT2000 Series User Manual page 157

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■2. Precautions (GT21)
(1) Terminal processing of power cables
Connect a stranded wire or a single wire directly, or use a rod terminal with an insulation sleeve.
Do not tighten the terminal screws in the specified torque range or more. Doing so can cause a failure or malfunction.
(a)
When connecting a stranded wire or a single wire directly
Twist the end of the stranded wire to prevent the elemental wires from protruding.
Do not apply solder plating on the wire terminal.
(b)
When using a rod terminal with an insulation sleeve
A wire with a thick sheath cannot enter the insulation sleeve smoothly. Select a wire referring to the figure of
external dimensions below.
PHOENIX CONTACT
(2) Tool
Tighten the power supply terminal using a commercially-available small screwdriver. The tip of the screwdriver must
be straight and as wide as the shaft, as shown in the figure below.
PHOENIX CONTACT
Insulation sleeve
2mm to 2.5 mm
(0.08inch) to (0.10inch)
Manufacturer
0.4mm
(0.02inch)
Manufacturer
Approx.
5 mm
(0.20inch)
Contact part
6mm
(0.24inch)
10.5mm to 12 mm
(0.42inch to 0.48inch)
Swage
CRIMPFOX UD6
Straight tip
2.5mm
(0.10inch)
Model
SZS 0.4 × 2.5
7.2 Power Supply Wiring to th GOT
7
7 - 5