Pto Switch; Diode Assembly - Toro Groundsmaster 3505-D Service Manual

Hide thumbs Also See for Groundsmaster 3505-D:
Table of Contents

Advertisement

PTO Switch

The PTO switch is located on the control panel (Fig. 12).
This rocker switch allows the decks to be engaged or
disengaged. Along with additional switches in the inter-
lock system, the PTO switch controls the solenoid valve
on the hydraulic manifold.
The Standard Control Module monitors the operation of
the PTO switch. If the ignition switch is in the ON position
and the PTO switch is moved to engage, the Module
PTO switch input LED should be illuminated.
Testing
The PTO switch terminals are marked as shown in Fig.
13. The circuitry of the PTO switch is shown in the chart
below. With the use of a multimeter (ohms setting), the
switch functions may be tested to determine whether
continuity exists between the various terminals for each
position. Verify continuity between switch terminals.
SWITCH
NORMAL
POSITION
CIRCUITS
ENGAGE
DISENGAGE

Diode Assembly

Diode D1 is used for circuit protection from inductive
voltage spikes when the deck drive solenoid is de--ener-
gized. The diode plugs into the wiring harness under the
control console.
Testing
The diode (Fig. 14) can be tested using a digital multime-
ter (diode test or ohms setting) and the table below.
Multimeter
Multimeter
Red Lead (+)
Black Lead (- -)
on Terminal
on Terminal
Female
Male
Male
Female
Groundsmaster 3505--D
OTHER
CIRCUITS
5 + 6
2 + 3
1 + 2
4 + 5
Continuity
YES
NO
Page 5 - - 13
2
1
Figure 12
1. Control panel
BACK OF PTO SWITCH
Figure 13
1
Figure 14
1. Diode
2. Male terminal
2. PTO switch
2
3
3. Female terminal
Electrical System