Active zones

You cannot arm an area unless all the zones in that area are normal, as an active zone would usually set off an
alarm. For example, all doors and windows must be closed.
If a zone is active while you try to arm or disarm an area, the keypad sounds seven quick beeps and displays the
active zones. You may have the ability to bypass active zones and arm the system.See
options
on page 10 for details.
Active zones are listed according to system programming. If Display Zones is enabled, then one zone and its
description will be displayed at the RAS. Press ON/EXT (see Figure 1 ) +MENU* (see Figure 1 ) to see the
next active zone and its description. If Display Zones is disabled, then a list of zone numbers will be displayed
at the RAS. Press the zone number and press ENTER (see Figure 1 ) to see its description.
One at a time:
List of numbers:
Table 6 lists the display options.
Table 6.
Active zone display options
Option
Update the list of active zones and display the next zones in
the list (if any).
Display the zone name in full.
Exit the menu option and return to the original display.
After determining the active zones, check those zones and correct the problem. Exit this display and try to arm
the system. If you are unable to close the zone, refer to
Note:
After trying to correct the problem and being unable to do so, you can press the bypass key to bypass active zones.
Active On 6.Front Door
NEXT or ENTER
Active On 6, 7, 9,
Zone No:
Action
Press ON/NEXT.
Enter the zone number and press ENTER.
Press CLEAR (see Figure 1 ).
System menu option 10, Bypass zone
Arming conditions and
on page 38.