GE NX-148E User Manual
Hide thumbs Also See for NX-148E:

Advertisement

g
GE Security
NetworX
Series
TM
NX-148E LCD keypad
User manual

Advertisement

Table of Contents
loading

Summary of Contents for GE NX-148E

  • Page 1 GE Security NetworX Series NX-148E LCD keypad User manual...
  • Page 2: Table Of Contents

    URNING THE DOOR CHIME ..................................19 ALKTEST PARTITIONED SYSTEMS OPERATION........................20 ......................... 20 IGHTS IN PARTITIONING MASTER MODE ........................21 ISPLAYS IN PARTITIONING MASTER MODE KEYPAD CONTROL TONES (BEEPS)........................23 SERVICE DISPLAY ................................ 24 NX-148E User manual Page 2 04/10/04...
  • Page 3 GE Security APPENDIX A – EVENT LOG ............................26 APPENDIX B – REFERENCE TABLES........................27 NX-148E User manual Page 3 04/10/04...
  • Page 4: Introduction

    AC Power removed to verify the battery is connected and adequately charged. 8. Care should be taken to plug in and restrain the AC transformer after testing. Please read the following information and instructions carefully before operating your security control system. NX-148E User manual Page 4 04/10/04...
  • Page 5: Glossary Of Terms

    [STAY] or [EXIT] key on the keypad control (for ARMING only) as programmed by the installing company. User Code A four (4) or six (6) digit entry code used to arm or disarm the system. NX-148E User manual Page 5 04/10/04...
  • Page 6: Keypad Display & Led's

    It will stay on until the central station has received the cancel report. NOTE: The cancel feature must be enabled. (See "Cancel/Abort Feature") Chime Light The chime light is “on” when the chime feature is “on”; “off” otherwise. NX-148E User manual Page 6 04/10/04...
  • Page 7: Emergency Activation Keys

    NOTE: Some Panic/Hold-Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center. Check with your installing company to determine how your security system will respond to the Panic/Hold-Up activation. NX-148E User manual Page 7 04/10/04...
  • Page 8: Keypad Functions

    [ ] to the right of the display to browse through the zones that are not normal. If you wish to bypass or unbypass one of these zones, press the [BYPASS] key while that zone is being displayed. When finished viewing the zones, press the [#] key to return to the code entry screen. NX-148E User manual Page 8 04/10/04...
  • Page 9: Arming Your System In The "Stay Mode

    AWAY mode by pressing the [EXIT] key, or arm in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc. NX-148E User manual Page 9 04/10/04...
  • Page 10: Changing Modes While System Armed

    Entering a code followed by the [CANCEL] key during or after an alarm report to the central station will cause the cancel light to come on. It will stay on until the central station has received the cancel report. NOTE: The cancel feature must be enabled. NX-148E User manual Page 10 04/10/04...
  • Page 11: Bypassing Zones

    Step 7 Pressing the [ ] [ ] scroll keys will display all bypassed zones. Press the [#] key to exit this viewing mode. NOTE: All zones will automatically be unbypassed each time the system is disarmed. NX-148E User manual Page 11 04/10/04...
  • Page 12: Unbypassing

    (Example: to bypass zones 4 en 5, press [0][4][0][5].) Step 5 Press the [BYPASS] key again. Step 6 The bypass light will stop flashing. NOTE: All zones will automatically be unbypassed each time the system is disarmed. NX-148E User manual Page 12 04/10/04...
  • Page 13: Adding And Changing User Codes

    If it rejects the code because of duplication or such, the sounder will beep 3 times. Step 5 If another “user code” needs to be programmed, return to Step 2. Step 6 Press the [#] key while the ready light is flashing to exit the User Code Programming Mode. NX-148E User manual Page 13 04/10/04...
  • Page 14: Assigning User Code Authority Levels

    Press [r] to save the data. The LCD will then prompt you for the next user code. Step 7 If another user code needs to be programmed, return to Step 3. If not, press [#] to exit this feature without saving the data. NX-148E User manual Page 14 04/10/04...
  • Page 15: Other Keypad Functions

    Alarm Memory Telephone # 1 Telephone # 2 Telephone # 3 Test Display test Light Control English (2) User PIN User Authority Detector Reset Log Review View Settings Set Date/Time Chime Walktest EXIT Silent Exit NX-148E User manual Page 15 04/10/04...
  • Page 16: View Zone Status

    [4] [3] to program/change telephone number 3 Step 3 The LCD display will prompt you for a code. Enter a master code. If the number cannot be changed, the keypad sounder will produde 3 short beeps. NX-148E User manual Page 16 04/10/04...
  • Page 17: Test Function (Optional)

    The LCD screen will again prompt you to “Select Light Number 0 - 9”. Step 5 Repeat Steps 2 and 3 until complete. Step 6 Press the [#] key to exit from the X-10 menu. NX-148E User manual Page 17 04/10/04...
  • Page 18: Change Languages

    This screen shows an opening of Partition 3 on September 25th at 5:27 p.m. by user 75. The [r] shows that this event is not programmed to be reported to the central monitoring station. NX-148E User manual Page 18 04/10/04...
  • Page 19: Adjusting The View/Brightness Of The Lcd

    Activate all sensors to be tested. Each activation of a sensor is confirmed with a “ding-dong” sound. The zonetexts of the sensors who have reacted, are displayed one by one on the screen. Step 4 Enter a [Mastercode] to exit the walktest mode. NX-148E User manual Page 19 04/10/04...
  • Page 20: Partitioned Systems Operation

    Remark: the cancel feature must be enabled by your installer. • SOUNDER: will sound if ANY area has the sounder on. This includes Entry delay, Exit delay, Chime, and Alarm. NX-148E User manual Page 20 04/10/04...
  • Page 21: Displays In Partitioning Master Mode

    For example: If Area 4 is armed, [r] [4] will disarm Area 4. If Area 4 is disarmed, [r] [4] will arm it. • Press [STAY] during the exit delay to bypass all interior zones in the exit delay. • To control the individual areas, refer to the following section. NX-148E User manual Page 21 04/10/04...
  • Page 22 If the keypad is sounding an alarm or the siren is running, it can be silenced by entering a code with the authority for the area(s) that are in alarm. NOTE: The [EXIT], [BYPASS], and [STAY] keys will only work if an individual partition is selected. NX-148E User manual Page 22 04/10/04...
  • Page 23: Keypad Control Tones (Beeps)

    Entering a valid code will silence the keypad sounder when it is pulsing. The arm/disarm state of your system will not change when entering a code to silence a pulsing keypad sounder. Please contact your installer if a trouble condition exists. NX-148E User manual Page 23 04/10/04...
  • Page 24: Service Display

    An auxiliary reporting device has failed to communicate. Aux. comm. fail Expansion The main power to an expansion power supply is not on. Power trouble Expansion An expansion power supply has a low battery. Low Battery NX-148E User manual Page 24 04/10/04...
  • Page 25 A wireless or multiplexed zone device is not reporting to the control. Lost, Press r Press [r] to identify the zone. Zone A zone is experiencing some form of trouble (probably wiring). Trouble, Press r Press [r] to identify the zone. NX-148E User manual Page 25 04/10/04...
  • Page 26: Appendix A – Event Log

    Listen In A listen in function has been activated. Service Start Service Start Technician is on site. Service End Service End Technician is off site. Code Entry Code Entry A code has been entered. NX-148E User manual Page 26 04/10/04...
  • Page 27: Appendix B – Reference Tables

    Function code Controls function (action) Entry/exit delay times in seconds : Exit delay time: Secondary Exit delay time: Entry delay time: Secondary Entry delay time: This system is , is not partitioned. This system counts ______ zones NX-148E User manual Page 27 04/10/04...
  • Page 28 Zone 77 Zone 118 Zone 37 Zone 78 Zone 119 Zone 38 Zone 79 Zone 120 Zone 39 Zone 80 Zone 121 Zone 40 Zone 81 Zone 122 Zone 41 Zone 82 Zone 123 NX-148E User manual Page 28 04/10/04...
  • Page 29 Zone 164 Zone 187 Zone 142 Zone 165 Zone 188 Zone 143 Zone 166 Zone 189 Zone 144 Zone 167 Zone 190 Zone 145 Zone 168 Zone 191 Zone 146 Zone 169 Zone 192 NX-148E User manual Page 29 04/10/04...
  • Page 30 EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT ©2004 © GE Security EMEA bvba. All rights reserved. GE Security EMEA bvba grants the right to reprint this manual for internal use only. GE Security EMEA bvba reserves the right to change information without...