System menu option 12, Test zone

Use this menu to test if an individual zone is operating correctly.
Note:
The test must be carried out within a predetermined time. If the test is not completed within this time, the option is
exited.
Test a zone
To test a zone, do the following:
1. Press MENU* (Figure 1), enter your user
PIN code, and press ENTER
(Figure 1).
2. Enter 12 (for menu 12) and press ENTER.
The display shows the test a zone window
(Figure 45).
Note:
If the zone is bypassed when a test is
requested, the system unbypasses the
zone, conducts the test, then returns the
zone to bypassed.
3. Enter the zone number for one of the
following four responses and press ENTER.
3a. The zone is normal (Figure 46).
3b. The zone is active (Figure 47).
3c. There is a faulty condition due to cable
tamper. The cabling to the zone shows an
OPEN circuit (Figure 48).
Figure 45. Test a zone
Test Individual Zone:
Zone No:
Figure 46. Normal test zone
NORMAL STATE on 12, Roller Door
Press ENTER
Figure 47. Active test zone
ACTIVE on 12, Roller Door
Press ENTER
Figure 48. Cable tampering, open
OPEN on 12, Roller Door
Press ENTER