absence. Leave the building immediately and call your alarm
company and/or the police from a safe location.)
CANCEL / ABORT FEATURE (Optional, see page 1)
The cancel light will flash during an abort delay time. If a code is entered
followed by the [CANCEL] key while this light is flashing, all abortable
reports will stop the communication process. Entering a code followed by
the [CANCEL] key during or after an alarm report to the central station
will cause the cancel light to come on. It will stay on until the central
station has received the cancel report.

BYPASSING ZONES

If you wish to bypass one or more zones, this must be done while the
system is in the disarmed state. The following steps are used for
bypassing zones:
Step 1
Press the [BYPASS] key.
Step 2
Enter user code, if required (optional). The bypass light flashes.
Step 3
Enter 1 or 2 digits indicating the zone you wish to bypass, i.e.
press the [1] key for zone 1, press [1]-[2] for zone 12.
Step 4
Press the [BYPASS] key again.
Step 5
The corresponding zone icon will illuminate indicating the zone
has been bypassed. Repeat steps 3 and 4 for any other zone(s)
that need to be bypassed.
Step 6
Press the [BYPASS] key again -or- press the [#] key to exit
the Bypass Mode. The bypass light will stop flashing upon
exiting the Bypass Mode.

GROUP BYPASS

By pressing the [BYPASS] key, followed by the [0] key, then the
[BYPASS] key again, all zones that are designated as group bypass zones
will be bypassed. Press the [BYPASS] key again -or- press the [#] key to
exit group bypassing.