Alliance system keypad
Hide thumbs Also See for AL-1103:
Table of Contents

Advertisement

Bypass an active zone
To Bypass an active zone, do the following:
1. Enter your PIN code to arm the system.
2. The LCD keypad displays a number from 1
to 256 (Figure 5 ).
3. Press the MENU* key (Figure 1 ) to see the
next active zone if more than one active
zones exists.
4. Press the Bypass/instant (Figure 1 ) key
once for each active zone to bypass all active
zones.
5. Press the ENTER (Figure 1 ) key after all
zones are bypassed to finish arming the
system.
Instant arm the system
To instant arm the system, do the following:
1. Enter your PIN code.
2. Press Bypass/instant key.
Arming the system in instant mode causes the area entry timer to be ignored, and alarms can occur instantly.
The system generates an alarm the instant the zone is faulted.
STAY arm the system
Areas armed using the STAY key, have no exit delay. All perimeter zones are supervised without delay. To
autobypass the interior zones and arm all of the perimeter zones for access, arm the system using the STAY key
(Figure 1 ). The STAY mode only works when perimeter zones are programmed in the system. Arming an area
using the STAY key eliminates exit delay.
Active Interior zones will be ignored when arming the system in STAY mode.
To arm the system in the STAY mode, do the following:
1. Enter your PIN code.
2. Press STAY key.
Programmed not to display areas assigned to your PIN code
If your system has not been programmed to display the areas assigned to your PIN code, all areas that were
disarmed are now automatically armed provided zone were not programmed for tamper. The display returns to
that shown in
System alarm status
successful.
on page 10. The area LEDs illuminate when the arming procedure is
Figure 5. Display active zones
Active zone 5