Code No.
Function
E7-30
Inverting unit shift motor
E7-31
Inverting shift transport motor
Check points
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Inverting unit PCB connector (CN601/604)
is shorted or broken.
(4) Inverting unit PCB is defective.
(5) (FP-D250/D350)
LVPS connector (CN13) is shorted or
broken.
(FP-D450/D600)
LVPS connector (CN13) is shorted or
broken.
(6) LVPS is defective.
(7) (FP-D250/D350)
CPU PCB connector (CN8) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (CN8) is shorted or
broken.
(8) CPU PCB is defective.
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Inverting unit PCB connector (CN601/602)
is shorted or broken.
(4) Inverting unit PCB is defective.
(5) (FP-D250/D350)
LVPS connector (CN13) is shorted or
broken.
(FP-D450/D600)
LVPS connector (CN13) is shorted or
broken.
(6) LVPS is defective.
(7) (FP-D250/D350)
CPU PCB connector (CN8) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (CN8) is shorted or
broken.
(8) CPU PCB is defective.