GE NX-10 Installer Manual page 83

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

Location
Term
2.6.1.1.4
Cross Zone Timer
2.6.1.2
Power
2.6.1.2.1
Batt Dynamic Test Duration
2.6.1.2.2
Mains Report Delay
2.6.1.2.3
Power Up Delay
2.6.1.3
Sounders
2.6.1.3.1
Internal Siren Timeout
2.6.1.3.2
Chime Time
2.6.1.4
Communications
2.6.1.4.1
Dialer Abort Delay
2.6.1.4.2
Listen-in Time
2.6.1.4.3
Phone Line Cut Delay
2.6.1.5.1
Programming Mode Timeout
2.6.1.5.2
Auto Arm Warning Time
2.6.1.5.3
Auto Arm Retry Timer
Definition
A menu option that sets the cross zone time in minutes.
This can be from 0 to 255 minutes, where 0 = no cross
zoning.
A menu entry that groups the timer options relating to
power events.
A menu option that sets the length of time that the control
panel performs the Dynamic Battery test. This can be
between 0 to 30 minutes where 0 is no test.
A menu option that sets the length of time between
detecting a mains failure on the control panel and sending
a report to the central station. The restore event is sent
four minutes after the mains is restored.
A menu option that sets the time between mains restore
after a power failure and the system powering up again.
This can be set from 0-60 seconds. 0 means no power up
delay.
A menu entry that groups timers for the internal siren,
external siren and chime duration on the keypad.
A menu option that sets the length of time the internal
siren rings before automatically cutting out. This time can
be between 0 and 255 minutes. When set to 0, the siren is
active until a valid code is entered on the keypad.
A menu option that sets the length of time that the chime
operates. This time can be set in 50 ms (1/20th second)
increments from 0-12 seconds. 0 = follows zone.
A menu option that groups timers for communication
events.
A menu option that creates a delay, programmed in
seconds, in reporting an alarm to the central station.
A menu option that sets the length of time the central
station can listen for sounds of intrusion by means of
microphones at the alarm site.
A menu option that sets the length of time before a phone
line cut is signalled after a phone line cut is detected.
A phone line fault is displayed in Service Check>Reset when
Phone Line Cut Delay = 0.
A menu option that sets the length of time the control
panel can be in programming mode. This time can be
between 1 and 255 minutes. When set to 0, the
programming mode times out after 15 minutes.
A menu option that sets the length of the warning signal
emited during auto arming. This time can be between 1
and 255 minutes, with 1 minute being a default value.
A menu option that sets the auto arm cycle timer. This time
can be between 1 and 255 minutes, with 45 minutes as a
default value.
NX-10 Installers manual
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents