Location
Term
2.4.1.1.1.6.1.3
Opening/Closing
2.4.1.1.1.6.1.4
Zone Bypass and Restores
2.4.1.1.1.6.2
Tamper/Fault
2.4.1.1.1.6.2.1
Tampers
2.4.1.1.1.6.2.2
Tamper Restores
2.4.1.1.1.6.2.3
Zone Trouble and Restores
2.4.1.1.1.6.2.4
Expander Trouble and Restores
2.4.1.1.1.6.2.5
Siren/Line Cut and Restores
2.4.1.1.1.6.2.6
RF Sensor Lost and Restores
2.4.1.1.1.6.2.7
RF Low Battery and Restores
2.4.1.1.1.6.3
Power
2.4.1.1.1.6.3.1
Power Trouble and Restores
2.4.1.1.1.6.3.2
Aux Short Circuit and Restores
2.4.1.1.1.6.4
Communications
2.4.1.1.1.6.4.1
Fail to Communicate
2.4.1.1.1.6.4.2
Test Reports
2.4.1.1.1.6.5.1
Program/Download
Definition
A menu option that sends a report to the selected phone
number stating when the system is opened (disarmed) and
closed (armed).
A menu option that sends a report to the selected phone
number when a zone is bypassed. A report is also sent
when the zone is restored (un-bypassed).
A menu entry that groups together the tamper and fault
events that are reported to the selected phone number.
A menu option that sends a report to the selected phone
number when a tamper occurs.
A report is sent when the previous tamper is no longer
active.
A menu option that sends a report to the selected phone
number when a zone fault condition occurs. A report is also
sent when the fault condition is no longer active.
A menu option that sends an expander fault and restore
report to the selected phone number.
A menu option that sends a report to the selected phone
number when a siren or phone line fault occurs. A restore
report is sent when the fault is fixed.
A menu option that sends a report to the selected phone
number when an RF sensor is missing. A restore report is
sent to the central station when the receiver receives a
valid signal from the lost transmitter.
A menu option that sends a report to the selected phone
number when a low battery condition occurs in an RF
sensor. A restore report is also sent when the low battery
condition is no longer active.
A menu entry that groups the power events that are
reported to the selected phone number.
A menu option menu option that reports mains failure,
mains restore, low battery and low battery restore events
to the selected phone number.
A menu option that sends a report to the selected phone
number when short circuit is detected. A restore report is
also sent when the short circuit condition is fixed.
A menu entry that groups together the communication
events that are reported to the selected phone number.
A menu option that reports a fail to communicate event to
the selected phone number.
A menu option that sends a test report to the selected
phone number at pre-programmed intervals. The units can
be set in days or hours.
A menu option that reports programming and

Hide quick links: