Segment 2
1 =
On: if siren driver should be a voltage output. Off: if on-board siren driver is
enabled
2 =
On: if sirens* sound for expander trouble
3 =
On: for zones to restore immediately. Off: for zones to restore only when the
siren is off or disarmed
4 =
On: if dynamic battery test is performed at arming. Off: if dynamic battery test
is performed at disarming (See location 40)
5 =
On: if battery missing test is performed every 12 seconds
6 =
On: if manual bell (BELL output, I/O and relays) test is performed during self
test function
7 =
On: if manual communicator test is performed during self test function
8 =
On: if Box Tamper terminals on the control panel are enabled
Segment 3
1 =
On: if box tamper report is enabled
2 =
On: if AC fail reporting is enabled
3 =
On: if low battery reporting is enabled
4 =
On: if Aux. power overcurrent report is enabled
5 =
On: if siren supervision report is enabled
6 =
On: if restore telephone line cut report is enabled
7 =
On: A+B Alarm. Off: cross-zoning
8 =
On: if expander trouble reporting is enabled
Segment 4
1 =
On: if fail to communicate report is enabled
2 =
On: if log full report is enabled
3 =
On: if autotest report is enabled
4 =
On: if start/end programming report is enabled
5 =
On: if end download report is enabled
6 =
On: if sensor low battery report is enabled
7 =
On: if sensor missing report is enabled
8 =
On: if autotest report is enabled ONLY when the system is armed
Segment 5
1 =
On: enable lost clock indication
2 =
Reserved
3 =
Reserved
4 =
On: will allow two trips on same cross-zone to activate an alarm
5 =
On: will not allow zones that are force armed to report bypass
6 =
On: enables silent exit option
7 =
On: activate "first disarm reporting" - "last arm reporting" for partitions
8 =
On: switch "summer/wintertime" and vice versa
Segment 6
1 =
Reserved
2 =
On: Use internal crystal for clock
3 =
On: zone activity monitor in hours (not in days)
4 =
On: enables first alarm logic
5 =
On: enables log protection
6 =
On: disables Clean Me report
7 =
On: siren* output is steady in case of fire alarm
8 =
On: valid user code will reset tamper memory
Segment 7
1 =
On: dial via GSM when phone line trouble (*)
2 =
On: Exit Error limited to Entry/Exit delay 1
3-8
Reserved
(*) Note: This feature is only used when the GSM module is enrolled by the panel and if the GSM module is used as
backup (GSM voice channel) for the PSTN dialer of the panel. Also telephone line monitoring needs to be
* BELL output only on NX-10
* BELL output only on NX-10
NX-10 Installers manual
101