6.2.3

I/O signal when CC-Link Ver.2 double setting is selected (Pr.544 = 12)

 Remote I/O (32 points)
Same as when Pr.544 = 0 (Refer to
 Remote register
Description
Address

Upper 8 bits
RWwn
Monitor code 2
Set frequency (0.01 Hz increments) /
RWwn+1
torque command
Link parameter
RWwn+2
extended setting
RWwn+3
Write data
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6

Setting "3" or "5" in Pr.804 during torque control under Real sensorless vector control or vector control sets torque command in RWwn + 1.

"n" indicates a value determined according to the station number setting.
page
45)
Refer
to
Lower 8 bits
page
Monitor code 1
59
59

Instruction code
59
59
60
60
60
60
Description
Address

Upper 8 bits
RWrn
First monitor value
RWrn+1
Second monitor value
RWrn+2
Reply code 2
RWrn+3
Read data
RWrn+4
Third monitor value
RWrn+5
Fourth monitor value
RWrn+6
Fifth monitor value
RWrn+7
Sixth monitor value
Refer
to
Lower 8 bits
page
62
62
Reply code 1
62
62
62
62
62
62
49