Device no.
Signal
RWw11,
RWw13,
RWw15,
Write data
RWw17,
RWw19
The display by rotations per minute can be enabled with Pr.37, Pr.144, and Pr.811. For details, refer to the Instruction Manual (Detailed)
of the inverter.
When Pr.541 Frequency command sign selection (CC-Link) = 1, the setting value has either + or -. When the setting value is negative,
the command is inversed from starting command.
Setting range: -327.68 Hz to 327.67 Hz (-327.68 to 327.67) 0.01 Hz increments
For details refer to
When Pr.128 = "50, 51, 60, 61", they are valid. If the data outside the range is set, the previous setting is retained.
Refer to the Instruction Manual (Detailed)
Set the data specified by the instruction code of RWw10, 12, 14, 16, and 18. (when required)
RWw10 and 11, 12 and 13, 14 and 15, 16 and 17, and 18 and 19 correspond each other.
Set "1" in RYF after setting the instruction codes (RWw10, 12, 14, 16, and 18) and the
corresponding register.
Set "0" when the write code is not required.
page
39.
of the inverter for d
Description
etails of Pr.128.
DETAILS OF INPUT AND OUTPUT SIGNALS
7