6.2
I/O signal list
6.2.1
I/O signal when CC-Link Ver.1 one station (FR-A5NC compatible) is occupied
(Pr.544 = 0)
Remote I/O (32 points)
Device
no.
RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command (terminal
RYn2
RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
Jog operation command (terminal Jog
RYn5
function)
Second function selection (terminal RT
RYn6
function)
Current input selection (terminal AU
RYn7
function)
Selection of automatic restart after
instantaneous power failure (terminal CS
RYn8
function)
RYn9
Output stop
Start self-holding selection (terminal STOP
RYnA
function)
Refer to
Signal
page
55
55
55
55
55
55
55
55
55
56
56
Device
no.
RXn0
Forward running
RXn1
Reverse running
RXn2
Running (terminal RUN function)
RXn3
Up to frequency (terminal SU function)
RXn4
Overload alarm (terminal OL function)
Instantaneous power failure (terminal IPF
RXn5
function)
Frequency detection (terminal FU
RXn6
function)
RXn7
Error (terminal ABC1 function)
RXn8
(terminal ABC2 function)
RXn9
Pr.313 assignment function (DO0)
RXnA
Pr.314 assignment function (DO1)
Refer to
Signal
page
57
57
57
57
57
57
57
57
57
57
57
I/O SIGNAL LIST