9.2
When two or more inverters are connected
The following system configuration shows how the cause of a fault can be checked with the LED status of the inverter
communication option (FR-A8NC) and countermeasures for the fault.
(In this example, assume SW, M/S, and PRM LEDs of the master module are OFF (master module is in normal operation).)
Power
supply
LED status
Inverters (FR-A8NC)
Master
unit
Station 1
Station 2
RUN
RUN
L.RUN
L.RUN
SD
SD
TIME
RD
RD
LINE
L.ERR
L.ERR
or
RUN
RUN
TIME
L.RUN
L.RUN
LINE
SD
SD
RD
RD
L.ERR
L.ERR
: On, : Off, : Flicker, : Any of on, flicker or off
Master
CPU
Station 1
module
FR-A8NC
Station 3
RUN
L.RUN
SD
Normal
RD
L.ERR
RUN
L.RUN
Contact faults of the FR-A8NC with the station
SD
1 inverter
RD
L.ERR
Station 2
FR-A8NC
Cause
HOW TO CHECK FOR ERROR USING THE LEDS
Station 3
FR-A8NC
Corrective action
Plug the FR-A8NC securely.
Check the connector.
91
9