O Signal List; Cc-Link Extended Setting (Pr.544) - Mitsubishi Electric FR-A8NC Instruction Manual

Plug-in option cc-link communication function
Hide thumbs Also See for FR-A8NC:
Table of Contents

Advertisement

6
I/O SIGNAL LIST
6.1

CC-Link extended setting (Pr.544)

Remote register function can be extended.
Pr.
Name
CC-Link extended
544
setting

The program used for conventional series inverter (FR-A5NC) can be used.
When RYD, RYE, and RYF turn on simultaneously, only one of them is executed.
The upper 8 bits of RWw2 are link parameter extended setting.

When using double, quadruple and octuple settings of the CC-Link Ver.2, station data of the master station must be set to double,
quadruple and octuple also.
(If the master station is CC-Link Ver.1 compatible station, the above setting can not be made.)

Refer to the PLC function programming manual.
NOTE
• The setting change is reflected after an inverter reset. (Refer to
44
I/O SIGNAL LIST
Initial
Setting
value
range
CC-Link Ver.
0
1
1
12

14
2

0
18

100
1
112

114
2

118

Description
Occupies one station (FR-A5NC compatible)
Occupies one station
Occupies one station double
Occupies one station quadruple
Occupies one station octuple
Occupies one station
Occupies one station double
Occupies one station quadruple
Occupies one station octuple
page 35
for inverter reset.)
Refer
to page
45

48
49
50
52
PLC function


Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

800 series

Table of Contents