Mitsubishi Electric FR-A8NC Instruction Manual page 64

Plug-in option cc-link communication function
Hide thumbs Also See for FR-A8NC:
Table of Contents

Advertisement

Device no.
Signal
Fault record
RWr9
(output frequency)
Fault record
RWrA
(output current)
Fault record
RWrB
(output voltage)
Fault record
RWrC
(energization time)
Reply code
RWr10 to
RWr19
Read data

When a value other than 9999 is set in Pr.430 under position control (Pr.800 = 3), pulse monitor is selected.
Output frequency of the faults history No. specified in RWw8 is stored.
Output current of the faults history No. specified in RWw8 is stored.
Output voltage of the faults history No. specified in RWw8 is stored.
Energization time of the faults history No. specified in RWw8 is stored.
When "1" is set in RYF, the reply codes corresponding to the instruction code RWw10, 12, 14, 16, and
18 are set. The value "0" is set for a normal reply and other than "0" is set for data fault, mode error,
etc. (Refer to
page
64.)
For a normal reply, the reply data to the instruction specified by the instruction code is set.
Description
DETAILS OF INPUT AND OUTPUT SIGNALS
7
63