Basic connection for monitoring or recording

TV monitor
(sold separately)
(Video signal connections)
Time lapse VCR or
Digital video recorder
(sold separately)
The peripheral devices (VCR, monitor, lens, etc.) and cables
are sold separately.
1
Make the video signal connection between the camera
and the monitor or time lapse VCR.
When using this unit, the supplied clamping core AA must be
installed on the power cord, in order to prevent
electromagnetic interference to the other devices connected.
2
Power supply choices
• When using a commercially available 24 V AC adaptor,
make sure to use a cable with an earth line (22AWG or
more) to connect to the grounding terminal. (Fig.1.)
• When using a DC 12 V power supply, make the
connections as indicated in Fig. 2.
(A)
: VIDEO IN
: VIDEO OUT
AC 24 V connection
AC24V
DC12V
AA
Fig. 1
CAUTION:
To prevent camera and/or power supply failure, pay close
attention to polarity when making the connections.
3
Insert the plug of this power supply into a wall outlet.
The POWER indicator (A) will light. Adjust the picture on the
monitor using the Brightness and Contrast controls.
DC 12 V connection
AC24V
GND
CLASS 2 WIR
DC12V
Fig. 2
GND
CLASS 2 WIR