C Alarm Output Setting (Alarm Out) - Sanyo VCC-ZM400P Instruction Manual

Colour ccd zoom camera
Hide thumbs Also See for VCC-ZM400P:
Table of Contents

Advertisement

OPTION SETTING
C
Alarm output setting (ALARM OUT)
1
ALARM SETTING
ALARM IN
ALM
POLARITY
NO
MOTION
OFF
DURATION
5S
ALARM OUT
OFF
POLARITY
NO
ALARM TIME
5S
LINE OUT
OFF
1
ALARM OUT setting
Use the cursor button (j or l) to move the cursor to
ALARM OUT, then use the cursor button (d or c) to
select "ON" or " OFF".
Available settings:
• ON: Output an alarm (for activation of buzzer or lamp)
• OFF: Does not output an alarm
2
POLARITY setting
Use the cursor button (j or l) to move the cursor to
POLARITY, then use the cursor button (d or c) to select
"NO" or "NC".
Available settings:
• NO: Normal open (Normally open so closed condition is
detected as input.)
• NC: Normal closed (Normally closed so open condition is
detected as input.)
2
ALARM SETTING
ALARM IN
ALM
POLARITY
NO
MOTION
OFF
DURATION
5S
ALARM OUT
OFF
POLARITY
NO
ALARM TIME
5S
LINE OUT
OFF
3
ALARM SETTING
ALARM IN
ALM
POLARITY
NO
MOTION
OFF
DURATION
5S
ALARM OUT
OFF
POLARITY
NO
ALARM TIME
5S
LINE OUT
OFF
PRESET
OFF
3
ALARM TIME setting
Use the cursor button (j or l) to move the cursor to
ALARM TIME, then use the cursor button (d or c) to
select the amount of time for external alarm output.
Available settings: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M,
5M
To close the menu screen or return to the previous
screen, select BACK or END for MENU and press the SET
button.
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents