Download Print this page

Sanyo VCC-ZM300P Service Manual

Colour ccd camera
Hide thumbs Also See for VCC-ZM300P:

Advertisement

SERVICE MANUAL
COLOUR CCD Camera

SPECIFICATIONS

Pickup device: 1/4"
Effective pixels: 752 (H) x 582 (V)
Horizontal resolution: Over 520 TV lines
Lens: 22 power zoom lens, f=4.0-88 mm (F1.6-3.8),
Electronic zoom and gearing, Zoom speed setting possible
Electronic zoom: 16 power (combined with optic zoom gives 352 power max)
Max zoom magnification setting possible, Vertical resolution ON/OFF setting
Autofocus: AUTO/MANUAL, AF area setting possible (3 step)
Iris control: AUTO/MANUAL, 1/2 EV steps
Synchronization method: Internal synchronization/Line lock, V phase adjustment possible
Lowest image illumination: 2.0 lx (F 1.6) at max AGC gain
0.06 lx (F 1.6) at x32 electronic sensitivity boost
S/N: Over 48dB
Backlight compensation: Multi-spot evaluative metering
5 spot centerweighted average metering, 48 multi-spot metering
Electric shutter: • Fast shutter speed mode (SHORT);
1/50, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000
• Slow shutter speed mode (LONG); x1, x2, x4, x8, x16, x32
Electronic sensitivity boosting: AUTO/OFF, works with auto iris, Up to x32 max setting possible
White balance: ATW/AWC/MWB
AGC gain: ON allows selection of ±0dB, +6dB, +9dB, -6dB
OFF allows manual adjustment from 0dB to 30dB
Motion detector: ON/OFF, ON allows setting of detection patterns on a 48 zone screen for
6 motion settings (size, masking, sensitivity, zoom, interval, alarm sign)
Privacy masking: ON/OFF, max of 4 masked locations, Password lock possible
Alarm input/output (back panel control terminals): Alarm input: 1 (for external alarm switch)
Alarm output: 1 (for sending a signal to the system controller or an alarm
detection device such as a buzzer)
Mirror image effect: Horizontally (H), vertically (V), horizontally and vertically (HV)
Camera ID: ON/OFF, 16 characters
View settings: 9 (0-8) screen files can be established, and each file can set
7 capturing characteristics such as iris
Communications: Coaxial control, RS-485
Operational temperature/humidity: -10 - 50 °C/below 90 %RH
Power source: 24 V AC, 50 Hz/12-15 V DC, Power consumption: 4.5 W, Weight: 380 g
The components designated by a symbol ( ! ) in this schematic diagram designates components whose value are of
special significance to product safety. Should any component designated by a symbol need to be replaced, use only the
part designated in the Parts List. Do not deviate from the resistance, wattage, and voltage ratings shown.
NOTE : 1. Parts order must contain model number, part number, and description.
2. Substitute parts may be supplied as the service parts.
3. N. S. P. : Not available as service parts.
Design and specification are subject to change without notice.
L5AA2/XE
PRODUCT SAFETY NOTICE
FILE NO.
VCC-ZM300P
(Product Code : 117 113 01)
(Europe)
CONTENTS
BOARD LOCATION ....................... 2
2. ADJUSTMENT ............................... 3
3. PARTS LIST ................................... 6
CIRCUIT DIAGRAM &
PRINTED WIRING BOARDS ........... C1
REFERENCE No. SM5310420

Advertisement

loading

Summary of Contents for Sanyo VCC-ZM300P

  • Page 1: Specifications

    FILE NO. SERVICE MANUAL COLOUR CCD Camera VCC-ZM300P (Product Code : 117 113 01) SPECIFICATIONS (Europe) Pickup device: 1/4” Effective pixels: 752 (H) x 582 (V) Horizontal resolution: Over 520 TV lines Lens: 22 power zoom lens, f=4.0-88 mm (F1.6-3.8),...
  • Page 2: Disassembly And Board Location

    1. DISASSEMBLY AND BOARD LOCATION CA3 board CA1 board CA2 board CA5 board 1. Three screws 2 x 4 CA4 board 20. Screw 3 x 6 2. Cabinet back 21. Screw 2 x 3 3. Three screws 3 x 4 22.
  • Page 3: Adjustment

    2-3. TABLE FOR SERVICING TOOLS 2. ADJUSTMENT 2-1. ADJUSTMENT CONDITION Ref. No. Name Part code 1. Use the 5,100K viewer for the subject. Color viewer VJ8-0007 2. Set the trigger signal of oscilloscope to VIDEO OUT, and Gray scale chart VJ8-0010 apply H sync unless specified.
  • Page 4 2-5. Frequency Adjustment (L-L) 2-8. Privacy Masking Compensation Adjustment location: CT201 (CA-2) Adjustment location: Measuring location: TP201 (CA-2) Measuring location: Measuring equipment: Digital multi meter Measuring equipment: Monitor display, privacy masking chart Subject: No designation Subject: No designation Adjusting method: Adjusting method: 1.
  • Page 5 2-10. Hue and Chroma Adjustment Adjustment location: Computer screen Measuring location: VIDEO OUT Measuring equipment: Oscilloscope, vectorscope Subject: Color bar chart 1. Select POS2 in the adjustment display, and project the color bar chart at the field angle of below figure. 2.
  • Page 6: Parts List

    3. PARTS LIST LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION 6015 FRAME (N.S.P.) ACCESSORIES & MATERIALS PARTS 6025 CHASSIS FRONT (N.S.P.) 6030 TERMINAL (N.S.P.) 9001 613 198 6176 7504 645 050 2866 LENS(ASSY) 9102 613 198 5490 INSTRUCTION MANUAL 7505 645 050 3740 OPTICAL FILTER...
  • Page 7 ELECTRICAL PARTS Note: 1. Materials of Capacitors and Resistors are abbreviated as follows ; Resistors Capacitors MT-FILM Metallized Film Resistor MT-POLYEST Metallized Polyester Capacitor MT-GLAZE Metallized Glaze Resistor MT-COMPO Metallized Composite Capacitor OXIDE-MT Oxide Metallized Film Resistor TA-SOLD Tantalum Solid Capacitor AL-SOLID Aluminum Solid Capacitor NP-ELECT...
  • Page 8 LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION IC206 409 323 9002 IC TC7S04FU C2017 403 207 0307 CERAMIC 1U Z 16V IC208 409 246 9707 IC LA6358NM C2018 403 327 1406 TA-SOLID 4.7U M 25V IC215 409 476 6903 IC BA7665FS C2019 403 285 6802...
  • Page 9 LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION C2261 403 346 2309 CERAMIC 0.1U K 10V R2071 401 224 9303 MT-GLAZE 1K JA 1/16W C2262 403 346 2309 CERAMIC 0.1U K 10V R2072 401 225 1405 MT-GLAZE 47K JA 1/16W C2301 403 285 6802 TA-SOLID...
  • Page 10 LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION R2206 401 226 1503 MT-GLAZE 0.000 ZA 1/16W (CONNECTORS) R2209 401 225 1207 MT-GLAZE 4.7K JA 1/16W CN202 645 002 3064 PLUG,8P (N.S.P) R2210 401 225 1207 MT-GLAZE 4.7K JA 1/16W CN203 645 027 0857 SOCKET,FPC 20P (N.S.P) R2215...
  • Page 11 LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION R3101 401 105 2607 MT-GLAZE 22 JA 1/16W C4083 403 162 9506 ELECT 4.7U M 35V R3102 401 166 8303 MT-FILM 1.2K DU 1/16W C4084 403 175 4505 ELECT 47U M 6.3V R3103 401 166 8105 MT-FILM...
  • Page 12 LOCATION PARTS NO. DESCRIPTION LOCATION PARTS NO. DESCRIPTION R4093 401 105 3000 MT-GLAZE 220K JA 1/16W C5002 403 232 9405 CERAMIC 0.01U Z 1KV R4094 401 250 5003 MT-GLAZE 100K DC 1/16W C5010 403 113 3805 CERAMIC 1000P K 50V R4095 401 105 2904 MT-GLAZE...
  • Page 13: Printed Wiring Boards

    CIRCUIT DIAGRAMS & PRINTED WIRING BOARDS TABLE OF CONTENTS OVERALL WIRING, BLOCK DIAGRAM & CIRCUIT DIAGRAMS OVERALL WIRING OVERALL CIRCUIT BLOCK DIAGRAM CA-1 CIRCUIT IC101, IC102 & IC103 BLOCK DIAGRAMS CA-1 CIRCUIT WAVEFORMS CA-2 CIRCUIT WAVEFORMS CA-2 CIRCUIT CA-3 CIRCUIT IC313 BLOCK DIAGRAM CA-4 CIRCUIT CA-5 CIRCUIT...
  • Page 14 NOTES: 1. All resistance values in "OHMS" unless otherwise noted. (K=1,000 ; M=1,000,000) µ 2. All capacitance values in " F" unless otherwise noted. µ p=pico farad ; ,u or U=micro farad µ 3. All inductance values in " H" unless otherwise noted. µ...
  • Page 18 V REGISTER...
  • Page 27 CA-5 BOARD (SIDE A) CA-5 BOARD (SIDE B)
  • Page 28 SANYO Electric Co., Ltd. Osaka, Japan May/’02...