Sharp IV-S30 User Manual page 156

Compact image sensor camera function and operation
Table of Contents

Advertisement

Distance and Angle Measurement
Select "DST&ANGL" on the MEAS-COND menu screen for the positional deviation measurement (page 4-2),
degree of match inspection (page 5-2), object identification by binary conversion (page 10-2), multiple
position measurement (page12-2), or multiple degree of match inspection (13-2), and press the SET key.
OBJECT: AUX
Æ The auxiliary points when mid point has been selected.
[ DIST&ANGLE COND]
1OBJECT
2AUXILIARY NO.
3COND.1
4COND.2
5AUX JUDGEMENT1 000.0~511.0
6AUX JUDGEMENT2 000.0~479.0
7RUN A TEST
REGISTER NO.
AUX.
OPS-MENU RETURN LOCK NUM-CALC OUT-COND
- The center point is the coordinate half way between points 1 and 2
that are specified on 3 and 4 (COND. 1 and 2).
Point 1 (X1, Y1)
Center point
Æ The auxiliary points when center of circle and center of gravity have been selected.
1OBJECT
2AUXILIARY NO.
3COND.1
14
4COND.2
5COND.3
6AUX JUDGEMENT1 000.0~511.0
7AUX JUDGEMENT2 000.0~479.0
8RUN A TEST
The center of the circle is the central
coordinate of three points positioned on
the circumference of the circle that are
specified between 3 and 5 (conditions
1 to 3).
To the next page
OBJECT: DIST
AUX DST ANGL
00(0~15) NO MID-PNT CIRC-C GRAV LINE-2P
INTERSECTION
MEAS-REGNO MDL0 AUX NO
MEAS-REGNO MDL0 AUX NO
[TEST RESULT] [OUTPUT]
X=030.0
Y=031.0
EXEC
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
X X X X X X X X X X
Point 2 (X2, Y2)
X1+X2
Y1+Y2
,
2
2
AUX DST ANGL
00(0~15) NO MID-PNT CIRC-C GRAV LINE-2P
INTERSECTION
MEAS-REGNO MDL0 AUX NO
MEAS-REGNO MDL0 AUX NO
MEAS-REGNO MDL0 AUX NO
EXEC
Point 1
Point 2
Point 3
Center of the circle
To page 14-4
OBJECT: ANGL
Specify the registration number for the
measurement program.
Select either Model 0 or 1 for that registration
number.
The auxiliary number selected in item 2 can
be specified here.
OK NO
Specify the conditions for evaluating the
coordinates (X/Y) of the midpoint. Select
EXEC on item 7 to run a test.
A circle will be displayed under the auxiliary
numbers that have been assigned.
Point 1 and 2 are coordinates output with
testing on the [EVALUTION COND]
menu, or measured on the MAIN OPS
MENU.
[TEST RESULT] [OUTPUT]
X=030.0
OK NO
Y=031.0
The center of gravity between points 1 to 3
that are specified between 3 and 5 is
calculated as the mean of the three
coordinates (conditions 1 to 3).
Point 1 (X1, Y1)
Center of Gravity
X1+X2+X3
3
14-2
To page 14-5
You have to specify these settings.
See the description above for the
item 7.
Point 2 (X2, Y2)
Point 3 (X3, Y3)
Y1+Y2+Y3
,
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents