Degree Of Match Inspection - Sharp IV-S30 User Manual

Compact image sensor camera function and operation
Table of Contents

Advertisement

Continued from the previous page
1REGISTER NO.
0(0~7)
2MEAS SHAPE(MDL0
RECTANGLE X-LINE Y-LINE
3REFIMG(MDL0)
NEW EXIST000(001~100)
4REFIMG ARE(MDL0)
MOVE UP.L(216,200) LO.R(295,279) CONTRAST SR
REG DISP
5SEARCH ARE(MDL0)
MOVE UP.L(216,200) LO.R(295,279)
6DTECT CRD(MDL0)
CENTER FREE(255,239)
7CONTR.PIXL(MDL0)
8MEAS SHAPE(MDL1
RECTANGLE X-LINE Y-LINE
9REFIMG(MDL1)
NEW EXIST000(001~100)
0REFIMG ARE(MDL1)
MOVE UP.L(
REG DISP
qSEARCH ARE(MDL1)
MOVE UP.L(216,200) LO.R(295,279)
wDTECT CRD(MDL1)
CENTER FREE(255,239)
eCONTR.PIXL(MDL1)
OPS-MENU RETURN LOCK EVALUATION
- Items 8 to e are displayed in the "2P-SCH" mode.
- The data in items 4, 5 and 7 vary according to the selection in item 2.
Selection in item 2
RECTANGLE
X-LINE
Y-LINE
Also the data in items 0, q and e vary according to the selection in item 8.
Ë Ë Ë Ë Ë Example of recording
- Example of a 2-point search in a rectangular measurement window
-
Example of when a horisontal line is selected as measurement shape
Crosshair cursor
(detection coordinates) Solid line (reference line) Dotted line (search line)
- Example of when a vertical line is selected as measurement shape
Crosshair cursor
(detection coordinates)
Select "EVALUATION" (or select "EVALUATION" on the [MEAS COND] menu) and press the SET key.
To the next page
) LO.R(287,279) CONTRAST SR
Data displayed in items 4 and 5
UP.L, LO.R
S.PT, E.PT
The reference image for model 0 (positioning)
The detection coordinates for model 0 (positioning)
The search area for model 0 (positioning)
The reference image for model 1 (object to be measured)
The search area for model 1 (object to be measured)
The detection coordinates for model 1 (object to be measured)
Solid line (reference line) Dotted line (search line)
5-3

Degree of Match Inspection

- Pages 3-4 and 3-5
- Page 4-3 (The settings are the same as for
the positional deviation measurement.)
- Page 3-7
- When "YES" is selected on the
"3SEARCH" line of the [MEAS COND]
menu (page 5-2), "5, q SEARCH ARE"
will be displayed.
When "NO" is selected, "5, q SEARCH
ARE" will not be displayed.
Data displayed in item 7
1 2 3
1 2
5