Sharp IV-S30 User Manual page 131

Compact image sensor camera function and operation
Table of Contents

Advertisement

Object Counting by Binary Conversion
Setting the measurement programs (pages 1-10 to 1-11: Select "CNT-BIN-OBJ" (object counting by
binary conversion) on the "MEAS SELECTION" line, and press the SET key.)
[TYPE MEAS COND]
6MEASUREMENT 1
[MEASUREMENT1]
1MEAS SELECTION
2SELECT CAMERA
3CHNG GRAY LEBEL
4SPACE FILTER
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
6MEASUREMENT 1
9
[MEAS COND]
1WINDOW
2REGISTER NO.
REGISTER NO.
3BINARY AREA COND
NUMERIC CALC
OPS-MENU RETURN LOCK EVALUATION NUM-CALC OUT-COND
Æ Setting (display) of binary area conditions
1WINDOW
2REGISTER NO.
REGISTER NO.
3BINARY AREA COND
NUMERIC CALC
Select any of the register numbers of binary area with circles.
When WINDOW has been
set to "NORMAL"
To the next page
CNT-BIN-OBJ C1
(MEAS-COND)
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD
INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
NO YES(00.0TIMES γ+ γ - CHNG-L INCRS-M)
NO
NUM-OF-TIMES 0(0~5)
CNT-BIN-OBJ
(MEAS-COND)
NORMAL BINARY-IMG-MASK
0(0~3) NO YES
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
NORMAL BINARY-IMG-MASK
0
NO
X : No setting
When WINDOW has been
set to "BINARY-IMG-MASK"
To page 9-4
1. Select "(MEAS-COND)."
When "MEASUREMENT 1" is selected.
COMPARE IMGS - Pages 3-23 to 3-25
- Page 3-14
- Page 3-10
1. Select a window type.
- BINARY-IMG-MASK - page 3-19
2. Enter a register number, and select "YES."
- When WINDOW is set to "BINARY-IMG-
MASK," only register No.0 can be selected.
3. Select the circle under the register whose
binary area conditions you want to set.
YES
When item 2 REGISTER NO. is set to "YES,"
a circle is displayed for the selected reigisters.
When CALC RESULT (see page 15-7) is set to
"YES," circles are displayed for the selected
registers.
9-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents