NEC Express5800 140Rd-4 User Manual page 118

Windows server 2003 x64 editions
Hide thumbs Also See for Express5800 140Rd-4:
Table of Contents

Advertisement

4-36
Multiple hard disks can be selected (simultaneous rebuilding.)
5.
The "FAIL" display for the hard disk selected starts blinking.
6.
When hard disk selection is completed, press F10 to start rebuilding.
7.
A confirmation screen for execution appears. Select "Yes" to start rebuilding.
8.
When the meter display in the "Rebuild Physical Drives in Progress" screen indicates 100%, rebuilding is completed.
9.
Press Esc to return to the TOP menu and exit MegaRAID Configuration Utility.
Setting hot spare
Procedure
1.
Install a hard disk to be used as hot spare, and then turn the server on.
2.
Start MegaRAID Configuration Utility to check each setting parameter.
Select "Objects" → "Physical Drive" from the TOP menu to display the "Objects - PHYSICAL DRIVE SELECTION
3.
MENU" screen shown below.
4.
Move the cursor onto the hard disk to be used as hot spare and press Enter.
5.
The "Channel X, Target X" screen appears. Select "Make HotSpare."
6.
A confirmation screen appears. Select "Yes."
7.
The hard disk display is changed to "HOTSP."
Install a hard disk
Start MegaRAID Configuration Utility
Check/set parameters
Exit MegaRAID Configuration Utility

Advertisement

Table of Contents

Troubleshooting

loading