23.1
Alternator - checking the stator winding
Condition
The stator is disconnected.
Preparatory work
-
Remove the seat. p. 82)
Main work
-
Pull engine electronics control unit O off of the holder and set it to one side.
©
R01415-10
Remove screws
Pull retaining bracket
©
of the battery forward and remove it.
Remove positive terminal cover.
m
! ft
©
I
R01416-10
Stator winding measurement I - check the resistance.
Measure the resistance between the specified points.
Stator, connector EN pin 1 - Stator, connector EN pin 2
EN
Q
Alternator
Stator winding resistance at: 20 °C
(68 °F)
0.15... 0.30 n
3
2
1
» If the indicated value does not correspond to the setpoint value:
- Change the stator.
Stator winding measurement II - check the resistance.
Measure the resistance between the specified points.
Stator, connector EN pin 1 - Stator, connector EN pin 3
600894-10
Q
Alternator
Stator winding resistance at: 20 °C
(68 °F)
0.15... 0.30 Q
» If the indicated value does not correspond to the setpoint value:
- Change the stator.
Stator winding measurement III - check the resistance.
Measure the resistance between the specified points.
Stator, connector EN pin 2 - Stator, connector EN pin 3
Q
Alternator
Stator winding resistance at: 20 °C
(68 °F)
0.15... 0.30 Q
If the indicated value does not correspond to the setpoint value:
- Change the stator.