Checking The Charging Voltage - Husqvarna 701 Enduro 2017 Repair Manual

Hide thumbs Also See for 701 Enduro 2017:
Table of Contents

Advertisement

15 WIRING HARNESS, BATTERY
122
Guideline
The charging current, charging voltage, and charging time must not be
exceeded.
Charge the battery regularly when the
motorcycle is not in use
3 months
Finishing work
-
Connect the battery, (il p. 120)
-
Mount the seat, (il p. 83)
-
Set the clock. (iS p. 139)
Checking the charging voltage
15.6
Condition
The battery must be fully functional and completely charged.
Preparatory work
-
Remove the seat, pp p. 82)
Main work
-
Pull engine electronics control unit O off of the holder and set it to one side.
O
p!
R01415-10
Remove screws
0
Pull retaining bracket
@
of the battery forward and remove it.
Remove positive terminal cover.
Start the motorcycle to check the function. (®S p. 14)
Ti
m
[ ^
IE
©
Ml
— R01416-10
Measure the voltage between the specified points.
Measuring point Plus (+) - Measuring point Ground (-)
V
+
Charging voltage
5,000 rpm
13.5... 15.0 V
» If the displayed value is less than the specified value:
-
Check the plug-in connections from the alternator to the voltage regulator.
-
Check the plug-in connections from the voltage regulator to the wiring
harness.
-
Check the stator winding of the alternator. (K8 p. 244)
» If the displayed value is greater than the specified value:
-
Change the voltage regulator.
Mount the positive terminal cover.
Position retaining bracket
@
Mount and tighten screws
0