Samsung AE050RXYDEG Installation Manual page 37

Air to water heat pump
Hide thumbs Also See for AE050RXYDEG:
Table of Contents

Advertisement

• After compressing it, pull both sides of the wire to make sure it is firmly pressed .
Method 1
Compress it 4 times
5 mm
5 . Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape .
Method 1
Insulation tape
40 mm
6 . Apply heat to the contraction tube to contract it .
Method 1
Contraction tube
7 . After tube contraction work is completed, wrap it with the insulation tape to finish .
Three or more layers of insulation are required .
Method 1
Insulation tape
• Make sure that the connection parts are not exposed to outside .
CAUTION
• Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have
the same level of withstand voltage with the power cable . (Comply with the local regulations on extensions . )
• In case of extending the electric wire, please DO NOT use a round-shaped Pressing socket .
‐ Incomplete wire connections can cause electric shock or a fire .
WARNING
Method 2
Compress it 4 times
5 mm
Method 2
Insulation tape
35 mm
Method 2
Contraction tube
Method 2
Insulation tape