Wiring
Between indoor unit and outdoor unit connection cable specifications(Common in use)
Communication cable
0 . 7 5mm², 2wires
f For the power Cable, use the grade H07RN-F or H05RN-F materials .
f
1-phase terminal block spec
AC power : M4 screw
L
10.1
f Power supply cords of parts of appliances for outdoor use shall not be lighter
f
than polychloroprene sheathed flexible cord . (Code designation IEC:60245
IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
f When installing the outdoor unit in a computer room or net work room,
f
server room or in the presence of risk of disturbance to the communication
cable, use the double shielded (tape aluminium / polyester braid + copper )
cable of FROHH2R type .
13.1
N
Communication : M4 screw
ENGLISH-32
Home server
0 . 7 5mm², 2wires
11.4
10.1