Installing the unit
Sea breeze
Sea
• Depending on the condition of power supply, unstable power or voltage may cause malfunction of the parts or
control system . (At the ship or places using power supply from electric generator, etc) .
CAUTION
f Do not install the Air to Water Heat Pump in following places .
f
• The place where there is mineral oil or arsenic acid . There is a chance that parts may get damaged due to burned resin .
The capacity of the heat exchanger may reduce or the Air to Water Heat pump may be out of order .
• The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet . The copper pipe or
connection pipe may corrode and refrigerant may leak .
• The place where there is a danger of existing combustible gas, carbon fiber or flammable dust . The place where thinner
or gasoline is handled .
• This device must be installed according to the national electrical rules .
• With an outdoor unit having net weight upper than 60kg, we suggest do not install it suspended on wall, but
CAUTION
considering floor standing one .
f If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position .
f
f Make sure that the water dripping from the drain hose runs away correctly and safely .
f
f When you install the outdoor unit at wayside, you should install it above 2m height or make sure that the heat from the
f
outdoor unit shouldn't be in direct contact with passersby . (The ground for application :The revision of regulation for
facility in building by the law of the Ministry of Construction and Transportation .
f While in installation or relocation of the product, do not mix the refrigerant with other gases including air or unspecified
f
refrigerant . Failure to do so may cause pressure increase to result in rupture or injury .
f Do not cut or burn the refrigerant container or pipings .
f
f Use clean parts such as manifold gauge, vacuum pump, and charging hose for the refrigerant .
f
f Installation must be carried out by qualified personnel for handling the refrigerant . Additionally, reference the regulations
f
and laws .
f Be careful not to let foreign substances (lubricating oil, refrigerant other than R-32, water, etc . ) enter the pipings .
f
f When mechanical ventilation is required, ventilation openings shall be kept clear of obstruction .
f
f For disposal of the product, follow the local laws and regulations .
f
f Do not work in a confined place .
f
f The work area shall be blocked .
f
f The refrigerant pipings shall be installed in the position where there are no substances that may result in corrosion .
f
Outdoor
unit
Protection wall should be constructed with a solid material that
can block the sea breeze and the height and width of the wall
should be 1 . 5 times larger than the size of the outdoor unit . (You
must secure more than 700mm of space between the protection
wall and the outdoor unit for air circulation . )
ENGLISH-14
Protection wall
Sea breeze
Sea
Outdoor
unit