Blade Deviation Detector & Calibration Procedure (Optional) - Sharp SW-165HT Instruction Manual

Table of Contents

Advertisement

Blade Deviation Detector & Calibration Procedure (Optional)
Blade Deviation Detector
Deviation Dectector Side Section
4-12
This device detects blade deviation. If the blade
deviates out of the tolerance range, the machine will
stop automatically.
※ [Remark] When this device is installed,
the cutting width will be reduced.
The blade deviation detected value and present values
are displayed on the HMI screen.
Before cutting, please make sure if the deviation value
is "Zero".
If not, please calibrate the deviation
detector before proceeding to cutting.
**Deviation Tolerance (Recommended):
±0.1~0.5 mm (±0.004"~0.02 ") 。
*Set up according to the tolerance range the users need.
How to Adjust
1. Loosen the nuts.
2. Adjust the proximity sensor until the blade
deviation value shown the display returns to zero.
(Please refer to the next page.)
3. Tighten the nuts.
How to Check
Put a thick ruler (0.1mm) between saw blade and
deviation roller for measurement. Also, check the
deviation tilt value; it should be 0.1mm.
Adjust the proximity sensor until the blade
deviation displayed on the control panel is zero.
If the deviation value not changed when adjusting
the proximity sensor or bearing, it means the
deviation detector with malfunction.
replace a new one.
Please clean the internal shell of deviation
detector sometimes for keeping dry and clean.