Deviation detector tolerance
Set-Up
[NOTE]
The information shown on HMI display: The format of HMI interface will be different from the
difference of model and software design.
Deviation
Value
Deviation Detecting
On/Off button
Picture B : Deviation calibration Value
Display
Make the proximity sensor connect
with power & adjust the proximity
sensor until the blade deviation
displayed on the control panel is 0
mm 。
Tolerance: ±0.03 mm (0.0012") 。
Picture C:
Deviation detector tolerance Set-Up &
On/Off button
 Deviation Value Set-Up:
- Set up the tolerance of deviation value; if
the value out of range when blading for
15 seconds, the machine will be
automatically full stopped with alarm
message.
 Deviation Detecting On/Off button:
- Turn On/Off the deviation detecting
function.
*Deviation Detector Tolerance (Recommended):
±0.1~0.5 mm (±0.004"~0.02 ") 。
4-13