Chapter 4 Connecting External Batteries; Precautions When Connecting External Batteries; Procedure For Connecting External Battery - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 4
Connecting External Batteries
This chapter describes how to connect external batteries to the OfficeServ 7200 sys-
tem for backup in case of power failure.
1

Precautions when Connecting External Batteries

The rated capacity of an external battery is DC 48 V and 45 AH per chassis. Batteries
should be connected to each chassis and a fuse (125 VAC, 5 Amp) should be positioned
between the output terminal of the battery and the chassis.
2

Procedure for Connecting External Battery

The procedure for using the supplied battery cable to connect an external battery to
the OfficeServ 7200 system is as follows. The end of the battery cable consists of a
white line and a black line (Fig. 4.1).
1.
Connect the white line of the battery cable to the (+) terminal of the battery,
and the black line to the (-) terminal.
2.
Connect the other end of the battery cable to the external battery socket on the
rear panel of the chassis. When using two or more chassis, prepare as many
external batteries as the number of chassis and connect the batteries to each
chassis.
© Samsung Business Communications
Connecting External Batteries
Take care when connecting an external battery:
Do not connect external AC power until the battery and the system are completely
disconnected.
Check the polarities (+, -) carefully when connecting external batteries to prevent
damage to the system.
Page 4-1