CHAPTER 1. Pre-Installation Information
1.2

Temperature/Humidity Conditions

The optimum conditions for temperature and humidity are as follows:
Operation temperature : 0 ~ 45 °C
Storage temperature : -10 ~ +50 °C
Humidity : 10~90 %
The system should be maintained in a cool area with no direct sunlight, and with
adequate ventilation to remove dust.
2

Grounding Conditions

The following precautions should be taken when grounding the OfficeServ 7200
system:
The grounding wire of the system should be correctly grounded to earth.
The flow of electric current between the grounding wire of the power plug and the
exposed metal surface of the system should be satisfactory.
When grounding additional, external equipment to the system grounding, the
grounding should be done through a single connection point.
3

Power Conditions

The system power supply module receives AC input power or battery power, and
supplies -48 V, -5 V, +5 V, +3.3 V, +12 V, and -56 V to the system chassis. The
maximum power consumption is 252 W per chassis.
Page 1-2
Grounding
- Do not connect the grounding wire of the OfficeServ 7200 system to a power con-
duit of the building.
- The standards for power and grounding should comply with the country standard
and the pertinent work should be carried out according to the country standard.
- External grounding is required to prevent personal injury or system damage
caused by lightning, static electricity, or voltage surge.
OfficeServ 7200 Installation Guide
© Samsung Business Communications