Device Paths Of Sparc M10-4 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

1. Stop an application to use an internal disk.
2. Remove the hardware RAID.
3. Identify whether the problem is related to the disk.
4. If the problem is not solved, replace all disks used for the hardware RAID.
5. Reconfigure the hardware RAID.
6. Restore data from a backup media.

Device Paths of SPARC M10-4

The following shows the device paths identified in SPARC M10-4.
When the CPU configuration at the initial
implementation is a two-CPU
The following shows the device paths when the CPU configuration at the initial
implementation is a two-CPU.
Note - The following device paths are applied when the configuration is changed from a
two-CPU to a four-CPU.
I/O device paths in SPARC M10-4 cabinet
Table 5-1
I/O device paths in SPARC M10-4 cabinet (at initial implementation: a two-CPU)
Device
LSB#0
Internal SAS
Internal HDD#0
Internal HDD#1
Internal HDD#2
Internal HDD#3
Internal HDD#4
Internal HDD#5
Internal HDD#6
Internal HDD#7
Internal LAN#0
Internal LAN#1
Device path
/pci@8000/pci@4/pci@0/pci@0/scsi@0
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p0
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p1
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p2
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p3
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p4
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p5
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p6
/pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@p7
/pci@8000/pci@4/pci@0/pci@9/network@0
/pci@8000/pci@4/pci@0/pci@9/network@0,1
Chapter 5 Information on SPARC M10-4 Hardware
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents