Problems resolved in XCP 2043
The following table lists the problems resolved in XCP 2043.
Table 3-2
Problems resolved in XCP 2043
SPARC
RTI No.
M10-1
RTIF2-130410-
x
004
RTIF2-130410-
005
RTIF2-130410-
006
SPARC
SPARC
M10-4
M10-4S
Description
x
x
The power may not be turned
on/off from the operation panel.
x
Executing the poweron -a
command leads to the failure of
power-on if more than one
PPAR is powered on or more
than one PPAR has failed in the
system that has multiple
physical partitions (PPARs).
x
If a crossbar box has failed in
the system that satisfies all the
following conditions, a crossbar
box may be degraded and the
operation may not be continued.
Two or more crossbar boxes
■
are configured.
Multiple PPARs are
■
configured.
Each physical partition
■
(PPAR) is configured with
multiple CPU memory units
(CMUU/CMUL).
Workaround
If you power on from the XSCF
shell, execute the poweron(8)
command. If you power off
from the XSCF shell, execute the
poweroff(8) command.
[How to restore]
If this event occurs, power off
the physical partition (PPAR)
by using the poweroff -f
command.
Specify the -p option to execute
the poweron(8) command and
turn on the power of each PPAR.
[How to restore]
If this event occurs, execute the
poweroff -f command to
forcefully power off the PPAR
whose power has stopped being
supplied during the middle of
the power supply process. Then
execute the poweron -p
command to power on the
PPAR.
There is no effective workaround.
[How to restore]
Execute the poweron -p
command to power on the
PPAR again whose power has
been turned off due to an error
in the crossbar box.
Chapter 3 Information on Software
25