Table 3-1
Problems that might occur with XCP 2043 and workarounds (continued)
SPARC
RTI No.
M10-1
RTIF2-130410-
003
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
24
SPARC
SPARC
M10-4
M10-4S
Description
x
If a physical partition (PPAR) is
powered on in the system that
satisfies all the following
conditions, other PPAR may
also be powered on.
The power supply
■
interlocking is enabled with
the setremotepwrmgmt(8)
command.
A node is created whose
■
SubNodeID is not set in a
power supply interlocking
management item.
Multiple PPARs are
■
configured.
Workaround
When the power supply
■
interlocking is unnecessary
Disable the power supply
interlocking with the
setremotepwrmgmt -c
disable and then delete the
power supply interlocking
setting with the
clearremotepwrmgmt(8)
command.
When the power supply
■
interlocking is necessary
If the system has multiple
PPARs, create a management
file of a power supply
interlocking by specifying a
PPAR-ID as a SubNodeID,
and then register the power
supply interlocking setting
with the setremotepwrmgmt
-c config.