5 ASSIGNMENT OF I/O NUMBERS
5 - 5
(b)
For 5-slot base unit/Q00JCPU: 5 slots are occupied
Q35B type main base unit
0
1
2
Q65B type extension base unit
5
6
7
8
Q65B type extension base unit
10 11 12 13 14
(c)
For 8-slot base unit: 8 slots are occupied
Q38B type main base unit
0
1
2
Q68B type extension base unit
8
9 10 11 12 13 14 15
(d)
For 12-slot base unit: 12 slots are occupied
Q312B type main base unit
0
1
2
Q612B type extension base unit
12 13 14 15 16 17 18 19 20 21 22 23
3
4
Three slots are not occupied
9
Three slots are not occupied
Three slots are not occupied
3
4
5
6
7
3
4
5
6
7
8