12 PROCEDURE FOR WRITING PROGRAMS TO BASIC MODEL QCPU
Connect GX Developer and
CPU module.
Move the RUN/STOP/RESET
switch of the CPU module to
the STOP position and switch
power on.
Choose "Program memory" in
online "write to PLC" of GX
Developer and write the
parameters and created program
to the program memory.
Write the program memory to
ROM in online write to PLC
(flash ROM) of GX Developer to
write the program memory data
to the standard ROM.
Make a reset with the RUN/
STOP/RESET switch of the CPU
module.
12 - 3
1)
END
Refer to the GX Developer manual.
ERR. LED is lit.
Write to PLC screen
Write program memory to ROM screen
Refer to the following manual and make a reset.
QCPU (Q Mode) User's Manual (Hardware)
Basic Model QCPU (Q Mode) User's Manual
(Hardware Setting, Maintenance and Inspection)
MELSEC-Q