APPENDICES
Number
Name
Stores the
Transmission
transmission speed
SD100
speed storage
specified in the serial
area
communication
setting.
Stores the
Communication
communication setting
specified in the serial
SD101
setting storage
area
communication
setting.
Stores the message
Message waiting
waiting time specified
time storage
SD102
in the serial
area
communication
setting.
Stores the data
Data sending
sending result when
SD110
result storage
the serial
area
communication
function is used.
Stores the data
Data receiving
receiving result when
SD111
result storage
the serial
area
communication
function is used.
SD130
SD131
SD132
Bit pattern in units of
16 points, indicating
SD133
Fuse blown
the modules whose
module
fuses have blown
SD134
0: No blown fuse
1: Blown fuse present
SD135
SD136
SD137
SD150
SD151
Bit pattern, in units of
SD152
16 points, indicating
the modules with
SD153
I/O module
verification errors.
verification error
0: No I/O verification
SD154
errors
SD155
1: I/O verification error
present
SD156
SD157
App - 10
Special Register List (Continued)
Meaning
K96: 9.6kbps, K192: 19.2kbps, K384: 38.4kbps,
K576: 57.6kbps, K1152: 115.2kbps
F
Online program correction setting
0: Disabled
1: Enabled
0: No waiting time
1 to FH: Waiting time (unit: 10ms)
Defaults to 0.
Stores the error code at the time of data sending using the serial communication
function.
Stores the error code at the time of data receiving.
• The numbers of output modules whose fuses have blown are input as a bit pattern
(in units of 16 points).
(If the module numbers are set by parameter, the parameter-set numbers are
stored.)
• Also detects blown fuse condition at remote station output modules
SD130
SD131
SD137
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation
• When the power is turned on, the module numbers of the I/O modules whose
information differs from the registered I/O module information are set in this
register (in units of 16 points).
(If the I/O numbers are set by parameter, the parameter-set numbers are stored.)
• Also detects I/O module information
15 14 13 12 11 10
SD150
0
SD151
0
SD157
0
• Not cleared even if the blown fuse is replaced with a new one.
This flag is cleared by error resetting operation
Explanation
6
15 14 13 12 11 10 9
8
7
1
1
0
0
0
0
0
0
0
(Y80)
(YC0)
1
1
0
0
0
0
0
0
0
(Y1A)
(Y1F0)
1
0
0
0
0
0
0
0
0
(Y1F
B0)
Indicates a blown fuse
9
8
7
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
( )
X Y
190
1
0
0
0
0
0
0
0
( )
X Y
1FE0
Indicates an I/O module verification error
5
4
3
2
1
0
Sumcheck yes/no
0: No
1: Yes
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
(Y1F
30)
6
5
4
3
2
1
0
1
0
0
0
0
0
0
( )
X Y
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
MELSEC-Q
Set by (When set)
S (Power-on or reset)
S (Power-on or reset)
S (Power-on or reset)
S (Error)
S (Error)
S (Error)
S (Error)
App - 10