PROGRAM 04
PORT/STATION NUMBER ASSIGNMENT
SELECT
= Port Number
INT = Station
Number
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
NOTES:
1. Follow instructions
in Table I-G (Section 200-096-301)
to enter this data.
2. Shaded portions of the table are for configuration
purposes
only.
3. If a station number is assigned, and 'ERROR"displays
on the LCD, the station number has already been assigned to another port.
4. Station numbers default to 200 - 295. New station number assignments
willnot activate on individualstation
LCDs until the handset
goes on/off hook.
5. If an assigned station number conflicts with a default feature access code, no error message is issued.
The stations LCD reflects
the conflicting number. When another station attempts to dial the number, the station will not ring. Instead, the feature activates.
6. If station numbers that conflict with feature access codes must be assigned,
use Program
05 to change the access code first.
7. The station connected
to port 05 has exclusive ability to program
the system.
8. PEKU ports 04, 12,20 and 28 may be configured
to support Door Phone Control Boxes (HDCBs).
See Program
77-l.
9. Door phone and modem (IMDU) station numbers are pre-assigned
as follows:
IMDlJ modem number:
l
Modem=
19
Door phone numbers:
. Port 04 = 151, 152, 153; Port 12 = 154, 155, 156
Port20=
157, 158, 159; Port28=
161, 162, 163
10. To insert a blank, press LED key 0 1; range programming
is possible.
11. PEKU circuit 3 or PESU circuit 8 is the optional BGM connecting port circuit. This BGM PCB must be installed in slot 01 in Release
2, but can be in any slot with Release
3 (see Program
19).
12. Port 99 = DISA COS port (Release 2); DISA Port 99 is normally used in Program
40,41, and 48.
13. May be used to connect two-CO line external conference
amplifier (customer-supplied)
to PEKU PCB (see Program
10-3).
14. Last port available
when using PCTUS control PCB.
15. PDKU requires Release
3 (PCTU3).
16. DlUs can be connected
to ports associated
with PDKU circuits 1 - 7.
I