PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 200-096-302
FEBRUARY1991
PROGRAM90
INITIALIZING PROGRAMS 00 - 97
Enter programming
mode
be initialized
LEDs must be lit
Key 1 and 2
LEDs must flash
EXIT
programming
mode
IMPORTANT
Initialize Programs 00 - 97 every time :
l
A new system is installed
l
To bring a system's programming
back to the default setting.
Specifiy the range as folio ws: m m m m F[
To initialize one program at a time, just enter the individual
program number, then m
NOTES:
1. Always
complete
Program
90 at new
system
installs,
before
programming
anything
else. Skipping
this step may cause erraticsystem
behavior.
2.
Follow instructions
in Table I-C (Section
200-096-301)
to c/ear this data.
3.
When
Program
90 is run, it will initialize
any program
or range
of
Programs
without cycling system power.
System power
may be cycled
to cause
Program
32 to initialize the programming
station with Intercom
autopreference.
This allows
the programming
station
to enter
the
Programming
Mode using the m
key ( B=
m
11 i 1 m.
WARNING!
Running this program will erase customer data.