The Station; Whether The; And The Of The - Toshiba STRATA DK24 Manual

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
4.72
For each class, choose
whether
the record
table
is used to record
allowed
office codes
in
memory
(ALLOWED)
or denied office codes not in
memory
(DENIED).
Enter the office codes
that
define the set.
4.80 Program 46-l 0 -,4O-Toll Restriction Class
Parameters (Classes 1 -, 4)
4.81
This program
defines
parameters
of each
Toll Restriction
class, including dialing plan restric-
tions and exceptions
to previous
restrictions.
4.82 Toll Restriction
exceptions
and dialing
plan
restrictions may be defined for each class.
Program
46-10
assigns
class 1 restriction
exceptions
and
parameters;
46-20 assigns class 2; 46-30 assigns
class 3; 46-40 assigns class 4. This program
also
relates to
Program 47. See Program 47
for more
explanation.
4.83
To define
the proper
parameters
for a Toll
Restriction
class, make the appropriate
selections
on the record sheet designated
for classes
1 w 4:
l
LED 01: 0 Restricted-Mark
an X next to LED
01 if operator
or operator-assisted
calls are
restricted
for the class being defined.
IMPORTANT
NOTE:
To allow
0 + dialing
(LED 01 must
be off),
codes 020
- 099 must
be allowed
in Pro-
gram 46, and digit free must
be allowed
in
Program
48. Warning-Allowing
0 + dial-
ing also allows operator-assisted
toll calls.
l
LED 02: 01 Restricted-Mark
an X next to
LED 02 if overseas
operator
or unassisted
overseas
operator
calls are restricted
for the
class being defined.
l
LED 03: 1 +AC+555 and AC+555 Allowed-
Mark an X next to LED 03 to allowthe
particular
class to call all restricted
area codes plus the
office code of 555, including
out-of-area
di-
rectory assistance
calls. Turning
the LED off
does not necessarily
deny information
calls.
This may also be accomplished
in the office
code table and/or the area/office
code excep-
tion tables.
. LEDsll
m 18: Area Code/Office Code Ex-
ception Tables 1
w 8-Select
the exception
tables that apply to the class being defined
by
marking
an X in the box. Exception
tables for
both area and office codes will be defined
in
Program 47.
..>,
i
'
NOTE:
Each class can be assigned
any or all of the
eight available
office code exception
tables.
4.90 Program 47-Toll
Restriction Exception
Office Codes Assigned by Area Codes (Table
l-8)
4.91
This program
defines
exceptions
to previ-
ously defined
office code restrictions
for up to eight
area codes, allowing
six-digit toll restriction.
Office
codes entered
in Tables 1 - 8 are opposite
of what
is defined
for the area code by
Program 46-2 -, 8.
For instance,
if
Program 46
denies area code 714,
entering
office codes 530 and 555 into an excep-
tion table for area code 714 will allow those office
codes.
4.92
Eight exception
tables
are available.
Each
area code with exception
office codes
requires
a
table.
Each table
may hold up to 800 exception
office codes.
4.93
Enter the areacode
and required office codes
on the record sheet.
4.100 Program 48-Station
Toll Restriction
Classification
4.101
This program
assigns a combination
of two
restrictions
to each
station
port defined
in the
system. Thefirstfeature
is Digit Restriction
and the
second
is Station
Restriction
Assignment.
4.102 Digit Restrict Code:
If Digit Restrict is en-
abled for a particular
station,
the station is able to
dial the number
of digits defined
in the
Program
45-l
toll restriction
dialing plan.
l
1: Enable Digit Restriction-Enter
1
in the
Digit Restrict
Code
column,
next to the port
number to enable the r$strictioti
for the station.
:
2-24