INSTALLATION-TELEPHONE
SECTION 200-096-207
FEBRUARY 1991
PCB is aligned
with the silk-screened
image
on the HVSI PCB.
2) Align the
P5
connector
on the HVSI PCB with
its receptacle
on the HVSU PCB (Figure 7-5).
Apply firm, even
pressure
to the PCBs to
ensure
that the connectors
mate
properly
(they click).
3) Position
the HVSU/HVSI
assembly
on the
standoffs
inside the base, and secure with the
two screws provided.
4) Connect
the HVSU/HVSI
PCBs to the elec-
tronic telephone
PCB as shown in Figure 7-3.
5) Reinstall
the electronic
telephone
base and
secure it with its four captive
screws.
2.20 Carbon Handset Option
2.21
If a carbon
type handset
is used with the
6500-series
electronic
telephone,
it is necessary
to cut two jumper
straps located on the main PCB
inside the telephone.
To cut the jumpers:
1) Remove
the base as described
in Paragraph
2.11.
2) Refer to Figure
7-3, and locate the carbon
straps
W201
and W202.
Cut both straps.
3) Reinstall
the electronic
telephone
base and
secure
it with its four captive
screws,
2.30 Beep Strap
2.31
If the beep strap is cut, the beep sound that
occurs
whenever
the feature
or dialpad
buttons
are pressed
is eliminated
(refer to Figures 7-1 and
7-3).
1) Remove
the four captive screws securing
the
6500-series
electronic
telephone
base to the
telephone
and remove
the base.
2) Locate and cut the beep strap.
3) Reinstall
the electronic
telephone
base and
secure in place using the four captive screws.
TO HVSU
.
CONNECTOR
ON MAIN PCB
INSIDE
TELEPHONE
HSVI
fl
FIGURE 7-5-HVSI/HVSU INSTALLATION
2.40 Microphone/Speaker
Threshold (speak-
erphone only)
2.41
If the speaker
cuts off frequently
because
high ambient
noise levels interrupt
conversations
during
handsfree
operation,
set the Room Noise
switch to the HI position
(see Figures 7-1 and 7-3).
1) Remove
the four captive screws securing
the
6500-series
electronic
telephone
base to the
telephone
and remove
the base.
2) Locate
the Room
Noise switch
and push it
carefully to the HI position
using a paper clip
or tip of a pencil.
3) Reinstall
the electronic
telephone
base and
secure in place using the four captive screws.
3 STATION INSTALLATION
REQUIREMENTS
3.00
Wiring Diagrams,
Chapter
9, provide
point-
to-point
wiring diagrams
for connecting
electronic
7-3