Operation; Mode Selection; Selecting A Mode; Program Mode - Toshiba Strata DK24 Installation And Maintenance Manual

Hide thumbs Also See for Strata DK24:
Table of Contents

Advertisement

REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
NOTE:
If the connection is not com pleted or com m u-
nication is unsuccessful, the remote term inal
displays: NO CARRIER. If this is th e c a s e ,
check that the equipment is installed per Para-
graphs 5.10, 6.10 of this section and try again.

6.30 Operation

6.31 Once communication is established between
the remote terminal and the IMDU, follow these
steps to enter the security code and receive the
MODE prompt.
NOTE:
H e r e a f t e r ,
CR
return or enter key, depending on the key-
board being used.
SPACE
bar. An empty square indicates one of several
characters will appear in that location (either
on the terminal 's screen or in a printout).
1) Set the keyboard for "Caps Lock" on.
2) Press the
CR
key.
The system responds, and the terminal
displays:
DK CONNECT
>CODE
*The software version number is identified in
Program 00.
3) Enter the 4-digit security code and press the
CR
key.
The system responds, and the terminal
displays:
OK
MODE

7 MODE SELECTION

7.00 Selecting a Mode

7.01 To enter an operating mode, establish com-
munication with the terminal, enter the security
code, and press
CR
to receive the MODE prompt.
NOTE:
Refer to Paragraphs 5.20 or 6.20 to accom -
plish the above.
w whenever is used, it means the
means the space
TABLE RM -B— PROGRAMMING PROMPTS
Mode Function
Mode Name
Program
Data Dump
Test
LCD Messages
Speed Dial No.
1) Set the keyboard for "Caps Lock" on (mode
name must be entered in capital letters).
2) At the MODE prompt, enter the desired mode
name (Table RM-B).
3) Press the
CR
key.
4) Verify the correct prompt return (Table RM-B).

8 PROGRAM MODE

8.00 General

8.01 Data governing overall system operation and
feature execution for the systems are stored in
read-only memory (ROM) and cannot be altered in
the field. However, the data controlling operation of
the system and station options are stored in ran-
dom-access memory (RAM) and can easily be
changed according to individual installation re-
quirements.
8.02 All options are controlled by selections made
in the System Record Sheets. An initialization
process is provided for verifying predetermined
system assignments. The installer can then pro-
ceed with any necessary changes.
8.03 Internal battery power is provided to prevent
loss of system data memory in the event of a power
failure.

8.10 System Record Sheets

8.11 Before system data can be programmed, the
System Record Sheets which contain the customer
data base must be available (see Programming,
Section 400-096-302).
-6-
Prompt Return
PROG
P
DUMP
D
TEST
T
MESG
(NONE)
REPT
R