6.2.5. Measure against noise

Because of the measure against the noise, please peel the sheath of the CC-Link cable, and the
ground clamp of the metal braid section at the case, and mount the ferrite core (recommendation
article: E04SR301334 * SEIWA ELECTRIC MFG.) on less than 30cm from the clamp position.
The connection method by controller is shown in the following.
(1) CR800-D controller
<CR800-D controller front>
Figure 6.2-4 Connection of the CC-Link cable (CR800-D controller)
(2) CR750-D/CR751-D controller
<CR750-D controller rear>
<CR751-D controller front >
Figure 6.2-5 Connection of the CC-Link cable (CR750-D/CR751-D controller)
CC-Link cable
CC-Linkケーブル
(Customer preparation)
(お客様準備)
CC-Link cable
CC-Linkケーブル
(Customer preparation)
(お客様準備)
CC-Link cable
CC-Linkケーブル
(お客様準備)
(Customer preparation)
25
Cable ground clamp
ケーブルアースクランプ位置
position *1
(アースクランプ付属品)
(Ground clamp
attachments)
Ferrite core
フェライトコア
(付属品)
(attachments)
Cable ground clamp
ケーブルアースクランプ位置
position *1
(アースクランプ付属品)
(Ground clamp
attachments)
フェライトコア
Ferrite core
(付属品)
(attachments)
Cable ground clamp
position *1
ケーブルアースクランプ位置
(Ground clamp
(アースクランプ付属品)
attachments)
Ferrite core
フェライトコア
(付属品)
(attachments)