Mitsubishi Electric KD Series User Manual page 96

Contact image sensor (cis)
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

Address
Register name
DeviceTemperature
7224
Mainboard
DeviceTemperature
7228
Ifboard
7230 DeviceError
7240 UserSet_BootSet_select R/W
7248 UserSet_Use_600dpi
724C UserSet_Use_300dpi
7250 UserSet_Use_200dpi
7254 UserSet_Use_150dpi
7300 DevicePassward
7400 STSP_Enable
STSP_MaxLine Period
7404
Counter
STSP_Prohibited Time
7408
Counter
TM-XH719C
Appendix A: Control register list ⑤
R/W
Val
R
-
R
-
R
0 to 7
0 to 3
R/W
0 to 1
R/W
0 to 1
R/W
0 to 1
R/W
0 to 1
R/W 0 to 65535
R/W
0 to 1
R/W 0 to 65535
R/W 0 to 65535
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Indicate an internal temperature (℃) of FPGA on Image processing
board (When using multiple image processing boards, this function
indicates the maximum value.)
Indicate an internal temperature (℃) of FPGA on I/F board. (When
using multiple image processing boards, this function indicates the
maximum value.)
Return "Error" indications about cooling fan and FPGA temperature.
0:Operating normally
'1' at 0bit: Error of cooling fan.
'1' at 1bit: Abnormal temperature of FPGA
'1' at 2bit: Abnormal temperature of FPGA on I/F board
Select a setting to boot after power-ON.
0:Factory Setting, 1:User Setting 1, 2:User Setting 2, 3:User setting 3
Correction data for 600dpi resolution
0:Disable / 1:Activete
Correction data for 300dpi resolution
0:Disable / 1:Activete
Correction data for 200dpi resolution
0:Disable / 1:Activete
Correction data for 150dpi resolution
0:Disable / 1:Activete
To access Dark/White correction data and γ-correction data
Switching prevention for exposure saturation On/Off
0:OFF /1:ON
Setting the period to judge whether occurring the condition
without external sync. signal or not.
Setting prohibited period for resuming to input sync. signal
Result
on Image processing board
Initial
-
-
-
0
1
0
0
0
-
0
3840
1280
96

Advertisement

Table of Contents
loading

Table of Contents