3-2-1 Preparation by users
⑦External illumination control cable
Non-illumination type CIS (CX-NL series) outputs a
trigger signal from connector L1, that is used to
synchronize the exposure timing of this product with an
external illumination. When using this trigger signal for the
external illumination control, prepare the cable to connect
with the external illumination.
Cable with following connectors are recommended.
Housing:
Contact pin:
CIS connector has DEU-9S-F0R (JAE),
Contact socket has 030-50640 (JAE).
Pin assignment of CIS connectors is shown below.
Non-illumination CIS(KD-CX-NL series)
Pin
Name
No
1
NC
2
3
4
OUT PULSE1
5
6
NC
7
8
OUT PULSE2
9
GND
TM-XH719C
3-2 Preparation
DEU-9P-F0R (JAE)
030-50641 (JAE)
I/O
Remarks
-
O
3.3V LVTTL
-
O
3.3V LVTTL
O
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【Reference】
Illumination trigger signal timing chart
External sync
signal
外部同期信号
Latency
同期遅延
Internal sync
signal
(内部同期信号)
Off
消灯期間
LedEffectivePeriod/N
LED pulse
signal
LED点灯パルス信号
LedPulseWidth/N
【Remarks】
Connector model of Non-illumination type CIS (CX-NL
series) is different from the connector model of built-in
illumination type CIS (CX series).
Line frequency
ライン周期
LedEffectivePeriod
*N= number of divisions
※N=分割数
LedPulseWidth/N