3-1-3 Both side view
1st-side Bracket
End-side Bracket
TM-XH719C
3-1 Installation
18.2 ± 0.1
18±0.2
~
~
18.2 ± 0.1
18±0.2
~
~
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【Remark】 How to install CIS into your device
1) Attach CIS to your system at the both end sides of CIS
by M3 screws . Focal point is defined the position from
the guide holes at the end of CIS .
2) There is the focal point of CIS with illumination at
52.0mm and without illumination at 51.4mm from the
guide holes .
3) For a reference, the working distance of the built-in
illumination type CIS is 12+/-1 mm.
4) There are 4screw holes(M3) each end side of CIS (total
8 screw holes). Use guide holes to make sure the CIS
is on the right position.
5) A chassis of CIS is made of aluminum. When tightening
a screw, be careful about thread damage of screw hole.
Material of screw
Iron (strength ranking 4.6)
Stainless (SUS 304)
Brass (C3601BD)
6) Shorter than 5.5mm is recommended for a length of the
pin for guide holes.
Tightening force [N・cm]
72 ± 7
63 ± 6
42 ± 4