Downloading Alarm Texts To The Du:s 1728 / 1735 / 1736 And Ext. Fbp:s 1826 / 1828; Real Time Clock (Rtc) - Panasonic EBL512 G3 Planning Instructions

Fire alarm system
Hide thumbs Also See for EBL512 G3:
Table of Contents

Advertisement

Panasonic Eco Solutions Nordic AB
MEW01472
Rev: -
16.27.2
16.28
Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x
Text column
Shows already programmed alarm texts. Texts can be typed / edited
here.
NOTE! If any alarm point shall have a different alarm text in one or
more of the "display units" 1826, 1828, 1735, 1736 or 1728
has to be typed in the Win512 version 2.7.x "Text editor":
Explanations for row 3:
Tech. no. column
Display unit connected to control unit "00", board "0" and display unit
(address) "00".
Zone-Address column
The Zone-Address that shall show another alarm text in the Display
unit D00000.
Text column
The text to be shown in the Display unit D00000 for the alarm point
001-02.
Downloading alarm texts to the DU:s 1728 / 1735 /
1736 and ext. FBP:s 1826 / 1828
The texts will be downloaded when the site specific data (SSD) is
downloaded via Win512 version 2.7.x.
The unit respectively has to be set in S/W mode xxxx – 1587

Real time clock (RTC)

Each control unit has an RTC.
presentation for fire alarms, faults, event logging and the time
channels 1-14. In a system with two or more control units in a TLON
network is the time in all control units synchronised.
105
Regarding text priority order etc. see Technical Description (chapt. "User
definable text messages") for the "display unit" respectively.
106
The calendar and clock can be set in any c.i.e. for the whole system.
Every day (at midnight) all calendars and clocks will be synchronised.
108
105
It is used for (date) and time
106
, the text